Chroma's passive component test solutions provide the instruments, systems, and automated test equipment required for production and reliability testing on various passive components such as inductors, transformers, capacitors, and resistors. They can also be used to test the LCR and insulation resistance parameters. Chroma's electrical safety test solutions encompass measuring instruments such as AC and DC withstand voltage, insulation, ground resistance, and dynamic leakage current required by electronic products and parts. The automated systems meet composite testing of medical equipment. The partial discharge testers detect abnormal discharges to ensure product quality. For various electromagnetic coils, Chroma also provides high-tech layer short test equipment and comprehensive test equipment, which simplifies the complex requirements of the test system.

Quick Menu

Système de test RLC / transformateur automatique

LecompteurLCRRF Model11090-030
  • CE Mark
  • Rohs 2 Compliant
Le compteur LCR RF
Model 11090-030
  • Paramètres de mesure : Z, θz, Y, θy, R, X, G, B, Ls, Lp, Cs, Cp, Rs, Rp, D, Q
  • Fréquences de test : 100 kHz - 300 MHz
  • Signal d'essai : -40 - 1 (dBm)
  • Vitesse de mesure élevée : 0,5 (ms)
  • Plage de mesure : 100 mΩ - 5 kΩ
HFLCRMeter Model11050Series
  • CE Mark
HF LCR Meter
Model 11050 Series
  • Fréquence de test: 75kHz~30MHz/1kHz~10MHz/60Hz~5MHz
  • Précision de base: 0,1 %
  • Temps de mesure: 7 ms
  • Interface standard RS-232 de gestionnaire et de stockage USB, interface LAN et GPIB H optionnelle
PontdemesureRLC Model11021/11021-L
  • CE Mark
Pont de mesure RLC
Model 11021/11021-L
  • Fréquence de test : 100 Hz, 120 Hz, 1 kHz, 10 kHz (11021) / 1 kHz, 10 kHz, 40 kHz, 50 kHz (11021-L)
  • Précision de base : 0,1 % (11021) / 0,2 % (11021-L)
  • Temps de mesure : 75 ms
  • Interface standard RS-232, interface GPIB et de gestionnaire optionnelle
PontdemesureRLC Model11022/11025
  • CE Mark
Pont de mesure RLC
Model 11022/11025
  • Fréquence de test : 50 Hz, 60 Hz, 100 Hz, 120 Hz, 1 kHz, 10 kHz, 20 kHz, 40 kHz, 50 kHz, 100 kHz
  • Précision de base : 0.1%
  • Temps de mesure : 21 ms
  • Interfaces standard RS-232, GPIB, et interface de gestionnaire
Capacimètre Model11020
  • CE Mark
Capacimètre
Model 11020
  • Fréquence de test : 100 Hz, 120 Hz, 1 kHz
  • Précision de base : 0.1%
  • Temps de mesure : 5 ms
  • Interface de gestionnaire
Testeurdetransformateurautomatique Model13350
  • CE Mark
Testeur de transformateur automatique
Model 13350
  • Fréquence de test: 20Hz~200kHz / 20Hz~1MHz
  • Précision de base: 0.1%
  • Fixations optionnelles pour différentes applications: Unité de balayage 20 canaux, boîtier de balayage 80 canaux, et banc d'essai de transformateur de courant
  • Interface standard RS-232, interface de stockage USB, interface LAN et USB-H optionnelle
Sourcedecourantdepolarisation Model1320/1320S/1320-10A
  • CE Mark
Source de courant de polarisation
Model 1320/1320S/1320-10A
  • Frequency Response:
    • 1320/1320S/1320-10A: 20Hz~1MHz
  • Output current:
    • 1320-10A: 0.001A~10.00A
    • 1320/1320S: 0.001A~20.00A
  • Directly controlled by LCR meter 11022/11025/3252/3302 (1320/1320S/1320-10A)
  • Standard GPIB and Handler I/F
Systèmedetestpourcourantdepolarisation Model11300
  • CE Mark
Système de test pour courant de polarisation
Model 11300
  • Réponse en fréquence: 20 Hz à 1 MHz
  • Courant de sortie: jusqu'à 300,0 A avec modules de 20,00 A
  • Précision de courant de sortie: 3%
  • Logiciel Windows pour l'analyse de courbe

Testeur de condensateur électrolytique

Testeurdecourantondulé Model11800/11801/11810
  • CE Mark
Testeur de courant ondulé
Model 11800/11801/11810
  • Fréquence de test: 100 Hz, 120 Hz, 400 Hz, 1 kHz (11800) / 20 kHz à 100 kHz (11801) / 20 kHz à 1 MHz (11810)
  • Courant ondulé et tension: 10 A, 90 V et 30 A, 30 V (11800) / 10 A, 15 V (11801/11810)
  • Tension DC: 0 - 650V (11800)/0 - 500V (11801/11810)
  • Interface standard RS-485

Scanner de test composant

Testeurdecomposantsparbalayage Model13001
  • CE Mark
Testeur de composants par balayage
Model 13001
  • Module de balayage à 40 canaux et unité esclave
  • Prend en charge 8 emplacements pour module plug-in, jusqu'à 320 canaux par unité
  • Prend en charge 8 unités esclaves pour la connexion à l'unité maître
  • Interface standard RS-232, Interfaces GPIB et USB

Testeur d’isolation

Testeurd'isolationdecellulesdebatterie Model11210
Testeur d'isolation de cellules de batterie
Model 11210
  • Tension d'essai: jusqu'à 1 KV (CC)
  • Courant de charge: 50 mA max.
  • Large plage de mesure du Courant de fuite (LC) (1pA ~ 20mA)
  • Test automatique avec séquence: charge-temporisation-mesure-décharge
Courantdefuiteducondensateur/Contrôleurd'isolement Model11200
  • CE Mark
Courant de fuite du condensateur/Contrôleur d'isolement
Model 11200
  • Tension DC: 1,0 V à 650 V / 800 V
  • Courant de charge: 0,5 mA à 500 mA
  • Mesure de courant de fuite: 0,001 uA à 20,00 mA
  • Interface standard RS-232, interface GPIB et de gestionnaire optionnelle

Système de test automatisé pour composants passifs

Systèmedetestducondensateur Model1820
Système de test du condensateur
Model 1820
  • Courant sinusoïdal haute fréquence: 1kHz~20kHz, 10kHz~200kHz
  • Tension de polarisation DC: 5000V max.
  • Test d'endurance et de montée en température des condensateurs
  • Test de résistance au courant du condensateur (balayage en fréquence)
  • Support avec contrôle logiciel
  • Module de test personnalisé