Power Rack is an integrated power solution within server racks, supplying electricity to all equipment. It consists of multiple Power Shelves connected in parallel, delivering high power outputs reaching hundreds of kilowatts. The architecture includes Power Distribution Units (PDUs), BBU Shelves, distribution boxes, and monitoring equipment to ensure efficient, safe, and stable power delivery for data centers and servers.

Given the high power capacity of server Power Racks, a comprehensive evaluation of the test laboratory requirements is essential. Chroma brings extensive experience and expertise to provide customized solutions covering parallel testing and assessment of equipment, site power usage and layout recommendations, air and water cooling planning, environmental heat dissipation, and thermal flow analysis. Recommended test architectures and equipment are as follows:

Chroma Server Power Rack Testing

High-Power AI Server Rack Testing up to 1.44MW

Chroma's 63200A Series DC Electronic Loads feature multi-unit synchronized dynamic current loading capabilities to accurately simulate server power operation. With the addition of synchronized signal boxes, up to 60 load units can be controlled simultaneously, enabling testing power levels up to 1.44MW. The system ensures dynamic synchronization timing error of less than 2 microseconds, providing precise and reliable test performance.

Energy Recovery to Reduce Energy Consumption

For long-duration burn-in testing, the Chroma 63700 Regenerative DC Electronic Load can be configured to feed energy consumed during testing back into the facility's power grid for reuse. With a feedback efficiency of up to 93%, this solution effectively reduces energy waste and lowers electricity costs.

Server Power Rack Testing

ServerPowerRackAutomatedTestSystem Model8000
Server Power Rack Automated Test System
Model 8000
Chroma 8000 Server Power Rack Automated Test System is a customized solution built upon the Chroma 8000 ATS platform. It is specifically designed for automated testing and validation of server power rack systems.
RegenerativeDCElectronicLoad Model63700Series
  • CE Mark
  • Rohs 2 Compliant
Regenerative DC Electronic Load
Model 63700 Series
  • Rated power: 6kW, 12kW, 18kW
  • Voltage range: 100V, 600V, 1,200V, 1,800V
  • Energy recovery efficiency: Up to 93%
  • Intelligent fan control
HochleistungsfähigeselektronischesDC-Last Model63200ASeries
  • CE Mark
  • Rohs 2 Compliant
Hochleistungsfähiges elektronisches DC-Last
Model 63200A Series
  • Nennleistung: 2kW, 3kW, 4kW, 5kW, 6kW, 12kW, 18kW, 24kW, max. 240 kW (parallel)
  • Spannungsbereich: 0-150V, 0-600V, 0-1200V
  • Strombereich: 2000A max. pro Geräteeinheit
  • Betriebsmodi CC, CR, CV & CP
DigitalerLeistungsmesser Model66205
  • CE Mark
  • Rohs 2 Compliant
Digitaler Leistungsmesser
Model 66205
  • Bietet eine Messgenauigkeit von 0,05% FS
  • Einphasen-Messanwendung
  • Spannungsbereiche: 15Vrms~600Vrms (6 Bereich)
  • Strombereiche: 5mArms~30Arms (10 Bereich)
  • Erfüllt die Vorgaben von ENERGY STAR/ EN 50564/ IEC 62301/ ErP
DigitalerLeistungsmesser Model66203/66204
  • CE Mark
  • Rohs 2 Compliant
Digitaler Leistungsmesser
Model 66203/66204
  • Bietet eine Messgenauigkeit von 0,1 % FS
  • Anwendung der dreiphasigen Messung
  • Spannungsbereich: 15 Vrms bis 600 Vrms (6 Bereich) 
  • Strombereich: 5 mArms bis 20 Arms (8 Bereich) 
  • Verdrahtungsmodus: 1P2W, 1P3W, 3P3W, 3V3A, 3P4W
RegenerativerNetzsimulator  Model61830/61845/61860/61800-100/61800-100(800VLN)
  • CE Mark
  • Taiwan Excellence 2018
Regenerativer Netzsimulator 
Model 61830/61845/61860/61800-100/61800-100(800VLN)
  • Ausgangsnennleistung: 30~60kVA, max. 300kVA (max. 5 Geräte in Parallelschaltung)
  • Dreiphasen-Ausgangsspannung 0~300V/30~100Hz
  • 4 volle Quadranten mit regenerativer Fähigkeit
  • Fähig zur Leitungsverzerrungssimulation